Synthetic EAL Solutions for Power Generation
Power Generation Needs High Performance Lubrication
Power generation is under simultaneous pressure to maximize uptime, modernize aging assets, and accelerate sustainability commitments. Hydro stations sit directly on waterways. Wind farms operate in remote, environmentally sensitive locations onshore and offshore. Gas turbines, steam plants, and reciprocating engines all run hydraulic and lubrication systems that can leak into the surrounding environment. Operators need lubricants that hit reliability and ESG targets at the same time.
BioMax™ delivers synthetic Environmentally Acceptable Lubricants (EALs) engineered for hydroelectric, wind, gas turbine, steam, and reciprocating-engine power generation. BioMax lubricants are readily biodegradable, exhibit low aquatic toxicity, are non-bioaccumulative, and deliver high film strength and oxidation stability for the long service intervals modern power plants require
The BioMax Advantage in Power Generation
Generation assets are designed for decades of service. The fluids that protect them need to deliver predictable performance, support sustainability mandates, and minimize environmental risk on every site.
- Stable Hydrocarbon Synthetic Base Technology: BioMax base oils resist hydrolysis and oxidation, supporting long fill life in turbines, hydraulic power units, and gear systems without sacrificing biodegradability.
- Aligned with Sustainability Mandates: BioMax EALs support EU Ecolabel, Blue Angel, Swedish Standard, and U.S. EPA VGP/VIDA criteria, providing documentation that aligns with utility, IPP, and offshore wind sustainability commitments.
- High Film Strength for Heavy Rotating Equipment: Advanced additive systems protect turbine bearings, gearboxes, and hydraulic governors under continuous high-load duty, supporting reliability targets.
- Drop-In Replacement with OEM Compatibility: Drop-in replacement chemistry and leading OEM approvals support conversion during normal outages, with no flushing requirement or seal upgrades on most systems.
Power Generation Applications and Equipment Coverage
Power generation portfolios span hydro, wind, gas, steam, and engine assets, all with distinct lubrication demands. BioMax offers application-specific synthetic EALs across the portfolio.
Kaplan and Francis turbine governors, wicket gates, runner hubs, intake gates, and submerged hydraulic actuators all operate in direct contact with surface water. BioMax synthetic hydraulic EALs protect these assets while supporting environmental commitments and watershed protection.
Wind turbine gearboxes, yaw and pitch hydraulics, and hub greasing points all require lubricants that perform reliably across wide temperature ranges and long service intervals. Offshore wind installation vessels add EAL-required marine duty to the program. BioMax synthetic gear and hydraulic EALs support both onshore and offshore wind assets.
Hydraulic power units, valve and damper actuators, cooling-water pumps, fuel and biomass handling drives, and outdoor material-handling equipment operate throughout the generating station, often near drains, cooling ponds, and discharge canals. BioMax synthetic hydraulic EALs, gear EALs, and greases protect these assets and bring environmentally sensitive areas of the plant under a single lubricant program.f
Comprehensive Reliability Solutions
Power generation assets are expensive to reach and expensive to take offline. The lubrication program should be designed around intervention cost, not unit price.
- Condition Monitoring: Sampling on hydro governor and gate hydraulics, wind gearboxes, and balance-of-plant systems, targeting the water ingress and oxidation that drive most fill changes.
- Technical Problem-Solving: Applications support for submerged actuators, wind gearbox service, and the long fill lives these assets demand.
- Consulting Expertise: Asset conversion planning sequenced around outage schedules, so changeovers happen when the unit is already down.
- Sustainability Roadmap: Environmental documentation that feeds permit compliance, watershed reporting, and corporate sustainability disclosure.
Best Practices for Power Generation Lubrication
When a fill change means a crane or a dewatering, the practices that extend fill life are the ones that matter.
- Convert During Planned Outages: Drop-in compatibility means conversion happens inside an outage already on the calendar rather than creating a new one.
- Design for Fill Life, Not Fill Cost: On assets that are hard to reach, oxidation stability and water tolerance decide total cost. Purchase price rarely does.
- Manage Water in Submerged Service: Hydro actuators and gate hydraulics live with water. Seal condition, breather selection, and sampling cadence determine how long a fill lasts.
- Plan Wind Greasing Around Access: Main, blade, and yaw bearing service is limited by crew access. Match product and interval to the access window you actually get.
- Trend Across the Fleet: Comparing the same asset type across units surfaces the outlier long before it fails.

Your challenge:
Assets in Direct Contact With Water You Are Accountable For
Hydro governors, wicket gates, and intake actuators operate in or above the water body the plant discharges to. Wind assets sit in exposed locations where a gearbox or bearing intervention means a crane and a lost generation day, and any release becomes a regulatory event.
OUR Solution:
EAL Coverage Across Hydro, Wind, and Balance of Plant
BioMax synthetic hydraulic fluids, gear oils, and greases protect submerged and exposed assets alike, holding oxidation stability for long fill life and resisting the water ingress that degrades conventional fluids in these services.
Your Reward:
Longer Fills, Fewer Interventions, Cleaner Compliance
Plants extend intervals on hard-to-reach fills, reduce unplanned interventions on hydro and wind assets, and carry verified environmental data into permit and sustainability reporting
Power Generation Equipment and Lubricant Recommendations
| Equipment/Application | Lubricant Type | BioMax Product | Key Benefits |
|---|---|---|---|
| Hydroelectric turbine governors and gates | EAL hydraulic fluid | BioMax™ Hydraulic EAL | Stable in the presence of water; readily biodegradable, low aquatic toxicity; protects against rust and corrosion in submerged service. |
| Hydroelectric wicket- gate and runner-hub hydraulics | EAL hydraulic fluid | BioMax™ Hydraulic EAL | Drop-in replacement with broad seal compatibility; high film strength under load reversal. |
| Wind turbine main gearboxes | EAL gear oil | BioMax™ Gear EAL | Long service life and high film strength for heavily loaded planetary and helical gear sets. |
| Wind turbine yaw and pitch systems | EAL hydraulic fluid / grease | BioMax™ MP EP Grease | Reliable performance across wide temperature ranges; corrosion protection for exposed hub and nacelle components. |
| Offshore wind installation vessels | EAL hydraulic / gear / stern tube | BioMax™ Hydraulic EAL / BioMax™ Gear EAL / BioMax™ Stern Tube EAL | Complete marine EAL coverage for vessel-side propulsion and deck systems. |
| Intake gates, spillway gates, penstock actuators | EAL hydraulic fluid | BioMax™ Hydraulic EAL | Rust and corrosion protection for intermittent-duty actuators submerged in or exposed to river and reservoir water. |
| Hydro turbine guide bearings and speed increasers | EAL gear oil | BioMax™ Gear EAL | High film strength and oxidation stability for continuously loaded bearing and gear sets in hydro service. |
| Wind turbine main, blade, and yaw bearings | EAL grease | BioMax™ MP EP Grease | Mechanical stability and corrosion protection for slow-moving, heavily loaded bearings in exposed nacelle and hub locations. |
| Bearings, linkages, pivots | EAL grease | BioMax™ MP EP Grease | High load capacity and water resistance for exposed plant grease points. |
BioMax offers a comprehensive synthetic EAL portfolio for power generation, including hydraulic fluids, gear oils, greases, and stern tube oils.
Featured BioMax Lubricants for Power Generation
BioMax Lubricants — Proven Results, Measurable Impact
Specialized Knowledge
Technical Support
Ongoing Innovation
Utilities, IPPs, and renewable power operators that standardize on BioMax synthetic EALs typically report:
- Reduced environmental risk on hydro stations, offshore wind sites, and watershed-adjacent plants.
- Verified sustainability performance that supports utility ESG reporting and renewable-energy commitments.
- Longer drain intervals and reduced lubricant consumption across the fleet.
- Tighter alignment with global regulatory frameworks for environmentally sensitive generation assets.
Schedule a Power Generation Lubrication Audit
Strengthen reliability, support sustainability commitments, and reduce environmental exposure across your generation portfolio. Contact a BioMax Technical Consultant to schedule a power generation lubrication audit and develop a plant-by-plant EAL conversion plan for your operation.